When the machine displays an error code there is a functional problem with the machine. Sometimes the code can be cleared by turning the machine off for a minute and then powering the machine back up. When powering down the machine, first turn off the on/off switch on the operation panel. This allows the machine to perform and complete its power down sequence. Wait until the panel has gone dark and any flashing buttons have stopped flashing. Then turn off the main power switch. Wait for a minute and turn the machine back on, first by the main power switch, then the on/off switch on the operation panel. If the code reappears call your service provider and inform them of the code that is displaying on the operation panel.
C1
C1 10 MAIN CHARGER TROUBLE
CE
CE 00 COMMUNICATION ERROR OTHER THAN CE-01-08
CE 01 NETWORK CARD IS NOT INSTALLED OR IS BROKEN
CE 02 THE SPECIFIED MAIL SERVER OR THE FTP SERVER IS NOT FOUND
CE 03 THE SPECIFIED SERVER SUSPENDS RESPONSE DURING TRANSMISSION OF IMAGES
CE 04 THE ENTERED ACCOUNT NAME OF THE FTP SERVER OR THE PASSWORD FOR AUTHENTICATION IS INVALID
CE 05 THE ENTERED DIRECTORY OF THE FTP SERVER IS INVALID
CE 06 THE SPECIFIED MAIL SERVER (POP3) IS NOT FOUND
CE 07 THE ENTERED ACCOUNT NAME OF THE POP3 SERVER OR THE PASSWORD FOR AUTHENTICATION IS INVALID
CE 08 THE SPECIFIED MAIL SERVER (POP3) SUSPENDS RESPONSE
E6
E6 11 CIS SHADING TROUBLE (WHITE CORRECTION)
E6 14 CIS COMMUNICATION TROUBLE
E7
E7 01 SYSTEM DATA TROUBLE
E7 02 LASER TROUBLE
E7 03 HDD TROUBLE
E7 06 DECODE ERROR TROUBLE
E7 10 CCD SHADING TROUBLE (BLACK CORRECTION)
E7 11 CCD SHADING TROUBLE (WHITE CORRECTION ALL PIXEL ADJUSTMENT)
E7 12 CCD SHADING TROUBLE (WHITE CORRECTION CENTER ADJUSTMENT)
E7 14 CCD COMMUNICATION TROUBLE
E7 50 LSU CONNECTION TROUBLE
E7 55 INCOMPATIBILITY CHECK ( ENGINE - PCU) DETECTION
E7 56 INCOMPATIBILITY CHECK ( ENGINE - PCU) DETECTION
E7 57 INCOMPATIBILITY CHECK ( ENGINE - PCU) DETECTION
E7 60 CONTROLLER CONNECTION TROUBLE
E7 65 INCOMPATIBILITY CHECK (MFP CONTROLLER DETECTION)
E7 66 INCOMPATIBILITY CHECK (MFP CONTROLLER DETECTION)
F1
F1 00 FINISHER COMMUNICATION TROUBLE
F1 02 FINISHER TRANSPORT MOTOR ABNORMALITY
F1 03 FINISHER OSCILLATION MOTOR TROUBLE
F1 08 FINISHER STAPLE SHIFT MOTOR TROUBLE
F1 09 FINISHER LOAD CAPACITY SENSOR TROUBLE
F1 10 FINISHER STAPLE MOTOR TROUBLE
F1 11 FINISHER PUSHER MOTOR TROUBLE
F1 15 FINISHER TRAY LIFT MOTOR TROUBLE
F1 19 FINISHER ALIGNMENT MOTOR TROUBLE
F1 31 FINISHER SADDLE FOLDING SENSOR TROUBLE
F1 32 FINISHER - SADDLE COMMUNICATION TROUBLE
F1 33 FINISHER PUNCH SHIFT MOTOR TROUBLE
F1 34 FINISHER PUNCH MOTOR TROUBLE
F1 37 FINISHER BACKUP RAM TROUBLE
F1 38 FINISHER PUNCH BACKUP RAM TROUBLE
F1 41 FINISHER SADDLE POSITIONING PLATE MOTOR TROUBLE
F1 42 FINISHER POWER ABNORMALITY
F1 43 CONSOLE FINISHER TRANSPORT MOTOR ABNORMALITY
F1 44 FINISHER STAPLE ROTATION MOTOR TROUBLE
F1 45 FINISHER / SADDLE FRONT STAPLE MOTOR TROUBLE
F1 46 FINISHER / SADDLE PUSH MOTOR TROUBLE
F1 51 FINISHER / SADDLE SENSOR CONNECTOR CONNECTION TROUBLE
F1 52 FINISHER MICRO SWITCH TROUBLE
F1 60 FINISHER - INSERTER COMMUNICATION TROUBLE
F1 61 INSETER EEPROM TROUBLE
F1 62 INISHER INSERTER / REVERSE SENSOR TROUBLE
F2
F2 00 TONER CONTROL SENSOR OPEN
F2 02 TONER SUPPLY ABNORMALITY
F2 04 IMPROPER CARTRIDGE (LIFE CYCLE ERROR, ETC)
F2 05 CRUM ERROR
F2 06 CRUM ID ERROR
F2 31 PROCESS CONTROL TROUBLE (PHOTOCONDUCTOR SURFACE REFLECTION RATE ABNORMALITY)
F2 32 PROCESS CONTROL TROUBLE (DRUM MARKING SCAN TROUBLE)
F2 37 DRUM MARKING SENSOR GAIN ADJUSTMENT ERROR
F2 39 PROCESS THERMISTOR BREAKDOWN
F2 46 DEVELOPING THERMISTOR BREAKDOWN
F2 47 ROOM TEMPERATURE THERMISTOR BREAKDOWN
F2 48 DEVELOPING HUMIDITY SENSOR BREAK DOWN
F3
F3 12 MACHINE TRAY 1 LIFT-UP TROUBLE
F3 22 MACHINE TRAY 2 LIFT-UP TROUBLE
F3 32 MACHINE TRAY 3 LIFT-UP TROUBLE
F3 42 MACHINE TRAY 4 LIFT-UP TROUBLE
F4
F4 38 38V VOLTAGE TROUBLE
F6
F6 00 MFP CONTROL - FAX COMMUNICATION TROUBLE (MFP CONTROL DETECTION)
F6 01 FAX EXPANSION FLASH MEMORY TROUBLE (MFP CONTROL DETECTION)
F6 04 FAX MODEM OPERATION ABNORMALITY
F6 20 FAX WRITE PROTECT CANCEL
F6 21 ABNORMALITY COMBINATION OF THE TEL/LIU PWB AND THE FAX SOFT SWITCH
F6 97 FAX BOX INCOMPATIBILITY TROUBLE
F6 98 COMBINATION ERROR OF THE FAX-BOX DESTINATION INFORMATION AND THE MACHINE DESTINATION INFORMATION
F7
F7 01 FAX BOARD EEPROM READ/WRITE ERROR
F9
F9 02 FAX CENTRO PORT CHECK ERROR
H2
H2 00 THERMISTOR OPEN / FUSING UNIT NOT INSTALLED (HL1)
H2 01 THERMISTOR OPEN / FUSING UNIT NOT INSTALLED (HL2)
H2 02 THERMISTOR OPEN / FUSING UNIT NOT INSTALLED (HL3)
H3
H3 00 FUSING SECTION HIGH TEMPERATURE TROUBLE (HL1)
H3 01 FUSING SECTION HIGH TEMPERATURE TROUBLE (HL2)
H3 02 FUSING SECTION HIGH TEMPERATURE TROUBLE (HL3)
H4
H4 00 FUSING SECTION LOW TEMPERATURE TROUBLE (HL1)
H4 01 FUSING SECTION LOW TEMPERATURE TROUBLE (HL2)
H4 01 FUSING SECTION LOW TEMPERATURE TROUBLE (HL3)
H5
H5 01 5 TIME CONTINUOUS POD 1 NOT-REACHED JAM DETECTION
L1
L1 00 SCANNER FEED TROUBLE
L3
L3 00 SCANNER RETURN TROUBLE
L4
L4 01 MAIN MOTOR LOCK DETECTION
L4 02 DRUM LOCK DETECTION
L4 03 FUSING MOTOR LOCK DETECTION
L4 04 DEVELOPING MOTOR LOCK DETECTION
L4 06 TRANSFER BELT SEPARATION MOTOR TROUBLE DETECTION
L4 30 CONTROLLER FAN MOTOR LOCK DETECTION
L4 31 PAPER DISCHARGING FAN TROUBLE
L6
L6 10 POLYGON MOTOR LOCK DETECTION
L8
L8 01 NO FULL WAVE SIGNAL
PF
PF 00 RIC COPY INHIBIT COMMAND RECEIVE
U1
U1 01 FAX BATTERY ABNORMALITY
U1 02 RTC READ ABNORMALITY (COMBINED USE AS FAX ON MFP CONTROL PWB)
U2
U2 00 EEPROM READ/WRITE ERROR (MFP CONTROL)
U2 11 COUNTER CHECK SUM ERROR (MFP CONTROL)
U2 12 ADJUSTMENT VALUE CHECK SUM ERROR (MFP CONTROL)
U2 22 SRAM MEMORY CHECK SUM ERROR (MFP CONTROL)
U2 23 SRAM MEMORY INDIVIDUAL DATA CHECK SUM ERROR (MFP CONTROL)
U2 50 HD SECTION INDIVIDUAL DATA CHECK SUM ERROR (MFP CONTROL)
U2 80 EEPROM READ/WRITE ERROR (SCANNER)
U2 81 MEMORY CHECK SUM ERROR (SCANNER)
U2 90 EEPROM READ/WRITE ERROR (PCU)
U2 91 MEMORY CHECK SUM ERROR (PCU)
U5
U5 30 DSPF TRAY LIFT UP TROUBLE
U5 31 DSPF TRAY LIFT DOWN TROUBLE
U6
U6 09 LCC LIFT MOTOR TROUBLE
U6 20 LCC COMMUNICATION TROUBLE
U6 21 LCC TRANSPORT MOTOR TROUBLE
U6 22 LCC 24V POWER ABNORMALITY ADDITION
U7
U7 00 RIC COMMUNICATION TROUBLE
- -
- - AUDITOR NOT READY